3 Advantages Of Using The ZE5 Cell Analyzer

Since the first laser was mounted to create the first flow cytometer, there has been a push for more – more lasers, more detectors, and more colors.

Why?

So researchers could ask more complicated questions to squeeze every iota of data out of rare events and precious samples, and so clinicians could expand the diagnostics capabilities of the technology. In addition, this trend has occurred so biotech companies could expand high-content screening for drug discovery.

Instrument manufacturers have brought to the table a plethora of different instruments, with capabilities to suit the needs of the researcher, at price points to make the accountants happy, with all improvements in hardware, software and automation to make the operator’s job easier. Often, these are based on an extension of the available equipment a vendor currently has.

Due to these improvements, the average researcher today has capabilities that were previously possible in only a very few specialized laboratories.

The Democratization of Flow Cytometry

What happens when an instrument manufacturer takes a step back, evaluates needs of different constituencies, and embarks on a journey to build a machine from the ground up, taking the best in technology and workflow to bring something novel to market that enables more users to gain access to the highest level capabilities?

A democratization of flow cytometry, and perhaps science in general.

As a core manager, some of the characteristics that are important in evaluating a potential new instrument include sensitivity, flexibility, and capacity. When thinking about training users, an easy to user interface is a must. If the software interface is too complicated, the system will sit in the corner and collect dust. Automation of common tasks from startup, to instrument cleaning, to quality control, are bonuses.

Researchers need to have a large number of lasers and detectors to ensure current panels can be run and new, expanded panels can be developed. Fast, automated acquisition is important to allow more to get done during the day. And, an easy to use software to reduce the barrier to access is a must.

This is a tall order because, in general, making one decision to improve a cell analyzer can limit the analyzer in other ways.

For example, fast acquisition with multiple lasers requires fast electronics and responsive optics, which can drive the cost of the instrument higher. Likewise, automation of common tasks can require complex software and monitoring devices, which may both increase price and decrease ease of access.

It may seem like an impossible task, but the team of Bio-Rad and Propel Laboratories, collaborated to bring the ZE5™ Cell Analyzer to the market and, with thoughtful design, the Analyzer answers these challenges, resulting in a high-end, easy to use, automated flow cytometer.

3 Advantages Of Using The ZE5 Flow Cytometer

Starting with the standard flow cytometry workflow, the ZE5 is the cytometrist’s cytometer.

On-board and automated quality control systems ensure the instrument starts up at the beginning of the day, and shuts down at the end of the day. More than that, the system has a novel development called the ‘ZE5-EYE’.

This system monitors all the laser spots, making sure the correct filter is in place and, more importantly, continues to monitor the system performance during the day, notifying users if there is a problem BEFORE they run their samples.

Overall, the ZE5 offers 3 unique advantages to cytometrists and end-users alike…

1. User Friendly Software With A Panel Design Tool

The ZE5’s advanced software system is called Everest™. But, don’t be fooled by its advanced capabilities.

Everest is easy to use and intuitive, which means even the most novice of users will not be intimidated as they learn to perform their flow cytometry experiments.

In addition, the software aids in the panel design process, and allows the researcher to view, on the instrument, the best fluorochrome/laser/filter combinations, which is essential for the development of a high-end polychromatic panel.

2. High-End Construction And Advanced Capabilities

With 5 lasers, the ZE5 has the range to take advantage of all commercially available dyes.

Another positive feature is the lasers are liquid-cooled. This helps maintain laser stability, especially on hot (and humid) days in the lab.

The fluidics have been re-thought too. For those familiar with the swappable fluidics of the S3e™ Cell Sorter also from Bio-Rad, it will come as no surprise that the ZE5 has a similar fluidics system. So, if a researcher has a long run, they don’t have to depressurize the system to refill the sheath tanks.

Instead, with the ZE5, you can hot-swap the fluidics with no loss of sample integrity during long acquisitions.

3. Lightening Fast Acquisition Speed Without Sacrificing Quality

Acquisition speed always has been a limitation on many systems. Slow systems increase the time to collect sufficient events to do rare event (and really rare event) analysis, and make rare event analysis tedious and time-consuming.

This is not the case with the ZE5, as seen in the figure below…

Figure 1: This graph shows the acquisition speed capabilities of the ZE5. Bangs Labs, Dragon Green Beads were used in a serial dilution to determine when cell count falls off the theoretical limit. The ZE5 outperforms other systems at higher acquisition speeds as it continues to acquire data into the 100,000 event per second range, whereas the competitive systems fall off around 20,000 events per second. Data and graph courtesy of Karen Helm, MT(ASCP) from the University of Colorado Cancer Center.

The ZE5 tops out at a level up to 100,000 events per second, making those 10-minute run times a thing of the past, in many cases. Even more impressive is the fact that the data spread and loss of events due to hard aborts and coincident events is tolerable at that high rate.

As mentioned, today’s researchers require a large number of lasers and detectors to ensure current panels can be run and expanded panels can be developed. The problem is that improving a cell analyzer in one direction can limit the analyzer in another direction. The ZE5 Cell Analyzer solves this problem with their new flow cytometer that includes user-friendly Everest software, high-end construction and capabilities, and blazing fast, high-quality acquisition speed.

To learn more about the ZE5 Cell Analyzer from Bio-Rad, and how to analyze your cells properly and faster acquisition speeds, click here.

Join Expert Cytometry's Mastery Class
Tim Bushnell, PhD
Tim Bushnell, PhD

Tim Bushnell holds a PhD in Biology from the Rensselaer Polytechnic Institute. He is a co-founder of—and didactic mind behind—ExCyte, the world’s leading flow cytometry training company, which organization boasts a veritable library of in-the-lab resources on sequencing, microscopy, and related topics in the life sciences.

Similar Articles

Getting A New Flow Cytometer? Try Before You Buy (And 2 Other Tips)

Getting A New Flow Cytometer? Try Before You Buy (And 2 Other Tips)

By: Tim Bushnell, PhD

There are 4 major ways to sort cells. The first way can use magnetic beads coupled to antibodies and pass the cells through a magnetic field. The labeled cells will stick, and the unlabeled cells will remain in the supernatant. The second way is to use some sort of mechanical force like a flapper or air stream that separates the target cells from the bulk population. The third way is the recently introduced microfluidics sorter, which uses microfluidics channels to isolate the target cells. The last method, which is the most common––based on Fuwyler’s work––is the electrostatic cell sorter. This…

5-Point Guide To Buying A New Microscope For Your Lab

5-Point Guide To Buying A New Microscope For Your Lab

By: Heather Brown-Harding, PhD

Have you ever noticed how painful it can be to purchase a new microscope? It would be hard to miss – this can be a frustrating process. A lot of scientists and students consider the new microscope hunt quite scary for a variety of reasons. It might be that you’re worried you won’t get the right microscope and that you’ll regret it, or you may find that dealing with salespeople, in general, makes you kind of uncomfortable. But remember, salespeople are just human beings like you and me, and if we can treat them as such, the whole process of…

Ask These 7 Questions Before Purchasing A Flow Cytometer

Ask These 7 Questions Before Purchasing A Flow Cytometer

By: Tim Bushnell, PhD

I am still convinced that my first cell sorter was possessed. The number of issues that I had with the system remains hard for me to believe, even after all these years. It had been purchased, in part, from one vendor because the sales rep for a competitor was nowhere to be found. At that time, I admit I wasn’t overly diligent in my research process. Since then, I’ve pinpointed some critical questions that need to be answered before purchasing a new instrument. At the end of the process, a shiny new instrument will arrive at your facility. Make sure…

Instrument Quality Control For Reproducible Flow Cytometry Experiments

Instrument Quality Control For Reproducible Flow Cytometry Experiments

By: Tim Bushnell, PhD

The flow cytometer is an integral component of any flow cytometry experiment, and special attention should be paid to ensuring that it is working correctly and consistently. As an end-user, the researcher should be able to sit down at a machine and know that it is performing the same way today as it was yesterday and last week. Equally important is that if any changes in instrument performance have occured, the end-user knows how they have been addressed and corrected, rather than letting them fester and potentially affect the results. Quality control measurements can include a variety of targets, such…

How to Optimize Flow Cytometry Hardware For Rare Event Analysis

How to Optimize Flow Cytometry Hardware For Rare Event Analysis

By: Tim Bushnell, PhD

Preparing for rare event analysis requires an understanding of the power and limitation of the instrument to be used. From how fast to run the fluidics, to how the signal is processed to the number of gates that can be used in the sorting experiment, each factor impacts the outcome of the experiment.

3 Ways The ZE5 Cell Analyzer Accelerates Flow Cytometry Research Opportunities

3 Ways The ZE5 Cell Analyzer Accelerates Flow Cytometry Research Opportunities

By: Tim Bushnell, PhD

Some technological advances are incremental, while others are significant game-changing tools that offer the researcher the ability to significantly improve current assays while allowing for new and novel avenues of research to be performed. With speed, sensitivity, and capacity to spare, the ZE5 fits into the game-changing category. Reduced carryover, increased speed of acquisition, and a large number of parameters all open up new and novel assays while improving the quality and reproducibility of ongoing ones.

3 Advantages FCS Express 6 Has Over Other Flow Cytometry Data Analysis Software Programs

3 Advantages FCS Express 6 Has Over Other Flow Cytometry Data Analysis Software Programs

By: Tim Bushnell, PhD

FCS Express is the ideal data analysis software program to use when analyzing your flow cytometry experiments because it is the most user-friendly program available that is both aligned with current data analysis best practices and maintains rigorous quality control standards.

How To Use A Threshold To Reduce Background Noise In Flow Cytometry

How To Use A Threshold To Reduce Background Noise In Flow Cytometry

By: Tim Bushnell, PhD

Getting a clear signal with reduced noise is an essential component to good data. Adding a threshold when acquiring flow cytometry data is one way to do that. It reduces the number of events by setting a bar that a signal pulse must clear before it is counted as an event. Depending on the importance of the data, the downstream applications for the data (or sorted cells) will dictate how critical the threshold is. In combination with proper sample preparation, appropriate thresholding will reduce debris and ensure best outcome.

How To Set And Monitor Optimal Voltages For A Flow Cytometry Experiment

How To Set And Monitor Optimal Voltages For A Flow Cytometry Experiment

By: Tim Bushnell, PhD

The best way to take out the fear and agony of setting voltages is to use some optimization methods. The peak 2 method is a useful and robust method of identifying optimal PMT voltage ranges. Refining that to the voltage walk with the actual cells and fluorochromes of interest will further improve sensitivity, which is especially critical for rare cell populations or emergent antigens. This article describes how to set up, monitor, and maintain optimal voltage settings for your flow cytometry experiment.

Top Technical Training eBooks

Get the Advanced Microscopy eBook

Get the Advanced Microscopy eBook

Heather Brown-Harding, PhD

Learn the best practices and advanced techniques across the diverse fields of microscopy, including instrumentation, experimental setup, image analysis, figure preparation, and more.

Get The Free Modern Flow Cytometry eBook

Get The Free Modern Flow Cytometry eBook

Tim Bushnell, PhD

Learn the best practices of flow cytometry experimentation, data analysis, figure preparation, antibody panel design, instrumentation and more.

Get The Free 4-10 Compensation eBook

Get The Free 4-10 Compensation eBook

Tim Bushnell, PhD

Advanced 4-10 Color Compensation, Learn strategies for designing advanced antibody compensation panels and how to use your compensation matrix to analyze your experimental data.