Top Flow Cytometry Instruments, Reagents & Software To Look Forward To In 2015 (1st Annual List)

Here at ExCyte–we are excited for all of the new flow cytometry instruments, reagents, and software you will have access to in 2015.

There are so many new and innovative products that we have been testing and looking into for you. These are just a few highlights of the great things coming your way in 2015.

I. Instrumentation

The field of flow cytometry is seeing various trends in instrumentation–on one end are smaller, more compact and more powerful instruments for the high end needs of researchers, and on the other end are easier to use instruments that make flow cytometry more accessible to researchers.

Leading the way for 2015 would have to be the Beckton-Dickenson Fortessa X50. This instrument, as reported at Cyto2014, was able to do over 20 fluorescent parameters. This offers the potential for high-parameter (Mass Cytometry level) data using fluorescent antigens. If this technology is expanded to cell sorting, it will allow better isolation of even more complex subpopulations.

The Attune NxT from Life Technologies is a system using acoustical focusing. Coupling the power to run at very high flow rates with lower spread of the CV’s compared to traditional flow, it uses up to fourteen fluorescent parameters. Exploring the power of this kind of system will be novel and it has a very small footprint as well.

Following the trend to use volumetric systems for fluidics, which helps drive the size and complexity of the instruments down comes the NovoCyte from Acea Biosciences, with three lasers and 13 fluorescent parameters, this is another instrument to consider for the lab tight on space.

Originally built by a Chinese company Xitogen, Beckman-Coulter acquired them and rebranded the instrument as the CytoFLEX. This small system was recently reviewed by Ryan Duggan. The system collects a second side scatter parameter off the 405 nm laser, which is potentially useful for those interested in micro particles. Also, as described in Ryan’s blog, this system uses APD rather than traditional PMTs.

Cell sorting has traditionally been the domain of large, complex machines. However, with the release of the Propel Avalon (now Bio-Rad S-3 cell sorter), the door has been open for cell sorters that are small and easier to use. Leading this trend is the Viva by Cytonome. This is a a true one-color bench top sorter at under $100,000 that will be a boon to those research groups using GFP as a marker in cell transfection.

The Tyto from Miltenyi-Biotech is an intriguing new cell sorter based on microfluidics replaceable cartridge. It has a small footprint, making it ideal for labs tight on space. Second, it does not use electrostatic deflection for sorting–thus reducing the biosafety concerns of aerosolized cells. While it can only sort one population on a time, since the system is low-pressure, sequential sorting is possible. Of the newer generation of smaller sorters, this has the most fluorescent parameters, which allows for isolation of more complex populations.

II. Reagents

Fluorescent nanocrystals have been both a boon and a bane for flow cytometrists. On the manufacturing size, they have difficulties in consistency and development of the best chemistry to link these organic crystals to biological tags. However, they expand the spectrum of what can be measured. For years these have been available from only a few vendors. Trilite nano crystals by QuantaCyte are an interesting new entry into the nanocrystal market. You can be sure we’ll be looking at how these perform compared to the traditional QDotos and eFluor Nanocrystals.

The Brilliant Violet dyes, developed by Sirigen and marketed by Biolegend and Beckton-Dickenson, remain the most exciting addition to the flow cytometrists toolbox. Brighter, with fewer issues compared to nanocrystals, they are rapidly replacing the nanocrystal to expand fluorescent. With the expansion of these fluorochromes into the ‘Brilliant Ultraviolet’ arena, cytometrists now have a reason to need a UV laser. True 18 fluorescent parameter analysis is becoming a reality with this expansion.

Another interesting area of development to watch will be the ability to measure RNA levels by flow cytometry. There are several companies marketing products in this space–all of which will allow the ability to measure mRNA levels in a phenotypic manner. eBioscience’s PrimeFlow RNA detection system and Advanced Cell Diagnostics RNAScope are two systems we’ll be watching closely.

III. Software

One of the most tedious tasks in flow cytometry is panel design–searching databases and determining which antigen/fluorochrome combinations are available and will work on your instrument of choice. The impending update and release of Fluorish 2.0 will be a great tool for designing antibody panels and keeping a virtual inventory of your antibodies. As is the newcomer in this space–Fluorofinder. Both of these programs are essential for complex panel design and should be in every cytometrist’s toolkit.

Updates and improvements to data analysis software are always of interest. Some, like the release of DIVA 8 (Beckton-Dickenson), were driven because of the changes in PC operating systems. Others, like FlowJo Enterprise, are designed to help with the complex analysis of large datasets.

Recent releases to Cytobank, including the integration of viSNE and channel-by-channel coloring of dot plots, are some intriguing new analysis tools that have been added to this freemium software package. For those performing CyTOF analysis, Cytobank and the SPADE platform remain one of the main tools for analysis of mass cytometry data.

Not to rest on their laurels, DeNovo’s team is hard at work on FCS Express 5. I am hearing some very good things about this package from the beta testers, including integrated statistical analysis platform. This would be a great boon for researchers and their workflow–performing the flow analysis and move the data seamlessly into a statistical analysis package. Finally, Flow Logic by Inivai remains a strong software analysis package. We’ve found it to be similar to FlowJo in data analysis logic with a more integrated GUI.

Competition leads to innovation–and that is good for the end user. Faster, cheaper, and easier instruments and software continue to be developed in the field, which can only serve to improve the researchers experience and ultimately data.

We’ll see how these intriguing products do in 2015, but at first glance, it should be a great year.

Join Expert Cytometry's Mastery Class
Tim Bushnell, PhD
Tim Bushnell, PhD

Tim Bushnell holds a PhD in Biology from the Rensselaer Polytechnic Institute. He is a co-founder of—and didactic mind behind—ExCyte, the world’s leading flow cytometry training company, which organization boasts a veritable library of in-the-lab resources on sequencing, microscopy, and related topics in the life sciences.

Similar Articles

Getting A New Flow Cytometer? Try Before You Buy (And 2 Other Tips)

Getting A New Flow Cytometer? Try Before You Buy (And 2 Other Tips)

By: Tim Bushnell, PhD

There are 4 major ways to sort cells. The first way can use magnetic beads coupled to antibodies and pass the cells through a magnetic field. The labeled cells will stick, and the unlabeled cells will remain in the supernatant. The second way is to use some sort of mechanical force like a flapper or air stream that separates the target cells from the bulk population. The third way is the recently introduced microfluidics sorter, which uses microfluidics channels to isolate the target cells. The last method, which is the most common––based on Fuwyler’s work––is the electrostatic cell sorter. This…

5-Point Guide To Buying A New Microscope For Your Lab

5-Point Guide To Buying A New Microscope For Your Lab

By: Heather Brown-Harding, PhD

Have you ever noticed how painful it can be to purchase a new microscope? It would be hard to miss – this can be a frustrating process. A lot of scientists and students consider the new microscope hunt quite scary for a variety of reasons. It might be that you’re worried you won’t get the right microscope and that you’ll regret it, or you may find that dealing with salespeople, in general, makes you kind of uncomfortable. But remember, salespeople are just human beings like you and me, and if we can treat them as such, the whole process of…

Ask These 7 Questions Before Purchasing A Flow Cytometer

Ask These 7 Questions Before Purchasing A Flow Cytometer

By: Tim Bushnell, PhD

I am still convinced that my first cell sorter was possessed. The number of issues that I had with the system remains hard for me to believe, even after all these years. It had been purchased, in part, from one vendor because the sales rep for a competitor was nowhere to be found. At that time, I admit I wasn’t overly diligent in my research process. Since then, I’ve pinpointed some critical questions that need to be answered before purchasing a new instrument. At the end of the process, a shiny new instrument will arrive at your facility. Make sure…

Instrument Quality Control For Reproducible Flow Cytometry Experiments

Instrument Quality Control For Reproducible Flow Cytometry Experiments

By: Tim Bushnell, PhD

The flow cytometer is an integral component of any flow cytometry experiment, and special attention should be paid to ensuring that it is working correctly and consistently. As an end-user, the researcher should be able to sit down at a machine and know that it is performing the same way today as it was yesterday and last week. Equally important is that if any changes in instrument performance have occured, the end-user knows how they have been addressed and corrected, rather than letting them fester and potentially affect the results. Quality control measurements can include a variety of targets, such…

How to Optimize Flow Cytometry Hardware For Rare Event Analysis

How to Optimize Flow Cytometry Hardware For Rare Event Analysis

By: Tim Bushnell, PhD

Preparing for rare event analysis requires an understanding of the power and limitation of the instrument to be used. From how fast to run the fluidics, to how the signal is processed to the number of gates that can be used in the sorting experiment, each factor impacts the outcome of the experiment.

3 Ways The ZE5 Cell Analyzer Accelerates Flow Cytometry Research Opportunities

3 Ways The ZE5 Cell Analyzer Accelerates Flow Cytometry Research Opportunities

By: Tim Bushnell, PhD

Some technological advances are incremental, while others are significant game-changing tools that offer the researcher the ability to significantly improve current assays while allowing for new and novel avenues of research to be performed. With speed, sensitivity, and capacity to spare, the ZE5 fits into the game-changing category. Reduced carryover, increased speed of acquisition, and a large number of parameters all open up new and novel assays while improving the quality and reproducibility of ongoing ones.

3 Advantages Of Using The ZE5 Cell Analyzer

3 Advantages Of Using The ZE5 Cell Analyzer

By: Tim Bushnell, PhD

Since the first laser was mounted to create the first flow cytometer, there has been a push for more - more lasers, more detectors, more colors. As a result, today’s researchers require a large number of lasers and detectors to ensure current panels can be run and new, expanded panels can be developed. This can be problematic because, in general, making one decision to improve a cell analyzer can limit the analyzer in other ways. It may seem like an impossible task, but the team of Bio-Rad and Propel Laboratories, collaborated to bring the ZE5™ Cell Analyzer to the market…

3 Advantages FCS Express 6 Has Over Other Flow Cytometry Data Analysis Software Programs

3 Advantages FCS Express 6 Has Over Other Flow Cytometry Data Analysis Software Programs

By: Tim Bushnell, PhD

FCS Express is the ideal data analysis software program to use when analyzing your flow cytometry experiments because it is the most user-friendly program available that is both aligned with current data analysis best practices and maintains rigorous quality control standards.

How To Use A Threshold To Reduce Background Noise In Flow Cytometry

How To Use A Threshold To Reduce Background Noise In Flow Cytometry

By: Tim Bushnell, PhD

Getting a clear signal with reduced noise is an essential component to good data. Adding a threshold when acquiring flow cytometry data is one way to do that. It reduces the number of events by setting a bar that a signal pulse must clear before it is counted as an event. Depending on the importance of the data, the downstream applications for the data (or sorted cells) will dictate how critical the threshold is. In combination with proper sample preparation, appropriate thresholding will reduce debris and ensure best outcome.

Top Technical Training eBooks

Get the Advanced Microscopy eBook

Get the Advanced Microscopy eBook

Heather Brown-Harding, PhD

Learn the best practices and advanced techniques across the diverse fields of microscopy, including instrumentation, experimental setup, image analysis, figure preparation, and more.

Get The Free Modern Flow Cytometry eBook

Get The Free Modern Flow Cytometry eBook

Tim Bushnell, PhD

Learn the best practices of flow cytometry experimentation, data analysis, figure preparation, antibody panel design, instrumentation and more.

Get The Free 4-10 Compensation eBook

Get The Free 4-10 Compensation eBook

Tim Bushnell, PhD

Advanced 4-10 Color Compensation, Learn strategies for designing advanced antibody compensation panels and how to use your compensation matrix to analyze your experimental data.